Resultado da pesquisa (3)

Termo utilizado na pesquisa Doppler echocardiography

#1 - Doppler echocardiography in goats Moxotó

Abstract in English:

This study describes the two-dimensional echocardiographic sections, M-mode cardiac dimensions, and Doppler flow indices in Moxotó goats. A total of 32 Moxotó goats were divided into four equal groups (n = 8) according to body weight class: G1 (5-10 kg), G2 (10-15kg), G3 (15-20kg) and G4 (>20kg). All animals underwent echocardiographic tests, two-dimensional and M-mode, and pulsed (PW), continuous (CW) and color flow (CF) Doppler. The spectral formation of echocardiographic images was satisfactory, although some adjustments were necessary to obtain adequate cuts/sections for goats above 20 kg. One-dimensional echocardiographic parameters (IVSD, IVSS, LVIDd, LVIDs, VPWd, LVPWs) and cardiac function index (EF and FS) showed a positive descriptive correlation with body weight in the categories studied. The septal separation of point E was constant among the weight categories investigated, ranging from 0.1 to 0.41cm. The Em/Am ratio was predominantly “>1”, with Emax> Amax in all weight categories, and not affected by the heart rate among the studied weight classes. The IVRT was also uniform among the studied weight classes. The individual flow rates of the aortic valve were higher than the maximum flow rate of the pulmonary valve. The ejection times of the aortic and pulmonary flows were positively correlated with increasing body weight, something also observed on the VTI of flow spectra, given the direct relationship of this variable with the stroke volume inversely to FC. The acceleration time (AT) of pulmonary blood flow was greater than the aortic flow, and directly related to increasing body weight and inversely with heart rate. Thus, the standardization of Doppler echocardiographic variables in goats, should always consider breed, age and body weight as well as repeatability and reproducibility studies and adoption of individual reference elements for reliable development of normal values.

Abstract in Portuguese:

Objetivou-se com este estudo reportar descrições acerca dos cortes ecocardiográficos no modo bidimensional, das dimensões cardíacas pelo modo unidimensional e dos índices de fluxo Doppler em caprinos da raça Moxotó. Foram utilizados 32 caprinos da raça Moxotó, distribuídos em quatro grupos por categoria de peso corporal, de igual número (n=8), em: G1 (5-10kg), G2 (10-15kg), G3 (15-20kg) e G4 (>20kg). Todos foram submetidos a um registro ecocardiográfico pelos modos bidimensional, modo-M, Doppler pulsado (PW), contínuo (CW) e de fluxo de cores (CF). A formação espectral das imagens ecocardiográficas foi satisfatória, contudo algumas adaptações foram necessárias para obtenção adequada dos cortes nos caprinos acima de 20 kg. Os parâmetros ecocardiográficos em modo unidimensional (IVSd, IVSs, LVIDd, LVIDs, VPWd, LVPWs) e índices de função cardíaco (EF e FS) apresentaram uma correlação descritiva positiva com peso corporal enquadradas nas categorias estudadas. A separação septal do ponto E, mostrou-se constante dentre as categorias de peso investigadas, variando entre 0,1 a 0,41cm em caprinos da raça Moxotó. A relação Em/Am foi predominantemente “ >1” em todos os caprinos estudados, com Emax > Amax em todas as categorias, não sendo sujeito a influência da frequência cardíaca dentre as categorias de peso estudados. O mesmo pode ser aplicado ao TRIV, que se mostrou uniforme dentre os intervalos de peso estudados. As velocidades de fluxo da valva aórtica individuais foram superiores a velocidade máxima do fluxo da valva pulmonar. Os tempos de ejeção dos fluxos aórtico e pulmonar apresentaram correlação positiva descritiva com o aumento do peso corporal. Condição também observada sobre o VTI dos espectros de fluxo, dada a relação direta desta variável com o volume sistólico inversamente à FC. O tempo de aceleração (TA) do fluxo pulmonar foi superior ao fluxo aórtico, sendo este relação direta com aumento do peso corporal por categoria estudada e inversamente à frequência cardíaca. Desta forma, a padronização das variáveis ecodopplercardiográficas na espécie caprina, deve sempre considerar particularidades relacionadas ao padrão racial, faixa etária e peso corporal, bem como estudos de repetibilidade e reprodutibilidade e adoção de elementos individuais referenciais para elaboração confiável de valores de normalidade.


#2 - Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation, 34(3):290-300

Abstract in English:

ABSTRACT.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied nondilated left ventricle. Myocardial dysfunction occurs in cats with HCM but less is known about dysfunctions in initial stages of HCM. A mutation in MYBPC-A31P gene has been identified in a colony of Maine Coon cats with HCM. However, the close correlation between genotype and phenotype still be inconclusive. Myocardial analysis by tissue Doppler imaging (TDI) is a noninvasive echocardiographic method to assess systolic and diastolic function that is more sensitive than conventional echocardiography. To evaluate diastolic and systolic function in cats with mutation, with or without ventricular hypertrophy, Maine Coon cats (n=57) were screened for mutation and examined with both echocardiography and TDI (pulsed tissue Doppler and color tissue Doppler methods). Then, were phenotypically classified in: normal (n=45), suspects (n=7) and HCM group (n=5); and genotypically classified in: negative (n=28), heterozygous (n=26) and homozygous group (n=3). Myocardial velocities (by pulsed and color tissue Doppler imaging) measured in the basal and mildventricular segment of the interventricular septal wall (IVS), left ventricular free wall (LVW), left ventricular anterior wall (LVAW), left ventricular posterior wall (LVPW) and radial segment of LVW, was compared among different groups. A decreased longitudinal Em velocities (pulsed tissue Doppler) at the mildventricular segment of LVW was observed in HCM cats compared with suspects and normal cats. A decreased longitudinal Em/Am (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. A significant increased longitudinal E/Em (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. And a significant decreased longitudinal Sm (color tissue Doppler) at the basal segment of the LVW was observed in heterozygous cats compared with negative cats, both without hypertrophy. There was a positive correlation between summated early and late diastolic velocities (Em/Am) and heart rate; and a positive correlation between Sm and Em velocities and heart rate, both in pulsed and in color TDI. TDI analyses are a new, valuable and reproducible method in cats that alone is not able to identify cats with mutation before myocardial hypertrophy. Despite high expectations regarding the use of TDI for early identification of individuals with HCM, there is still need for larger studies with greater numbers of individuals.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar as funções sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografias convencional e tecidual (nas modalidades Doppler tecidual pulsado e Doppler tecidual colorido). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais, enquanto que os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos quando comparados com os negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca, assim como correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite diferenciar gatos portadores da mutação antes do desenvolvimento de hipertrofia ventricular. Apresenta utilidade como auxílio no diagnóstico em fases iniciais, mas, apesar da expectativa para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.


#3 - Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs, 30(7):586-592

Abstract in English:

ABSTRACT.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22±19.38m/s; AO MV= 0.72±0.08m/s; AO VTI= 0.14±0.02m; AO AT= 38.80±11.29ms; AO ET= 197.90±24.77ms; Pul PV= 0.95±0.18m/s; Pul MV= 0.63±0.10m/s; Pul VTI= 0.13±0.02m; Pul AT= 70.97±18.87ms; Pul ET= 203.70±28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22±19,38m/s; V. Me. AO= 0,72±0,08m/s; VTI AO= 0,14±0,02m; TA AO= 38,80±11,29ms; TE AO= 197,90±24,77ms; V. Max. Pul= 0,95±0,18m/s; V. Me. Pul= 0,63±0,10m/s; VTI Pul= 0,13±0,02m; TA Pul= 70,97±18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV